With experience across hundreds of MSR retrofits and installations, our team can improve efficiency, performance and extend the service life.

  • Efficiency

    Configuration and technical parameters designed for increased power output.

  • Reliability

    Over 40 years of excellence across an extensive installed base. 

  • Adaptability

    Suitable for a wide range of sizes and system design requirements.

Thermal Cycle Efficiency

MRS Nogent-sur-Seine

MSR in Nogent-sur-Seine nuclear power plant. Source: EDF

Thermal Cycle Efficiency

MSRs remove moisture and superheat the steam, thus avoiding erosion corrosion and droplet impingement erosion in the low pressure turbines. Our solutions provide:

  • Efficiency - As an integral part of the turbine generator package, the MSR configuration and technical parameters are designed for increased power output. 

  • Adaptability - Can be adapted to all existing reactor outputs up to 1,900 MWe and can meet a wide range of sizes, arrangements and system design requirements. 

  • Reliability - Its extensive installed base (200 units in operation) demonstrates 40 years of excellent operation. First-generation MSRs are still in operation today. 

  • Availability - Increases the availability of power generation, thanks to its track record of high reliability and reduced maintenance. It also offers quick-start operation

MSR solutions

Typical Reference Solutions for: 1,000 MW 1,200 MW 1,700 MW
Installation Horizontal Horizontal Vertical
Type 2 Reheat Stages 2 Reheat Stages 2 Reheat Stages
Quantity per TG Set 2 2 2
Cycle Steam Inlet Massflow (kg/s) 620 700 980
Inlet Pressure (bar a) 10 11 12
Moisture Separation - - -
Inlet Moisture (%) 14 14.5 15
Outlet Moisture (%) 0.5 0.5 0.5
1st and 2nd Stage Reheater - - -
Tube Type U-finned U-finned Straight-finned
Tube Material Ferritic Stainless Steel Ferritic Stainless Steel Ferritic Stainless Steel
Tube-tubesheet Joint Expanded/Welded Expanded/Welded Expanded/Welded
MSR Shell - - -
Diameter (m) 4.3 4.3 5.8
Straight Length (m) 18.6 18.8 16.2
Material Carbon Steel Plate Carbon Steel Plate Chrome Moly Plate
Weight - - -
In Operation (tons) 260 265 440
Flooded (tons) 520 540 860

Our condenser offerings

We have been engineering, commissioning and delivering condensers worldwide for over 50 years.

Learn more